PARAMETER SYMBO
L
MIN TYP MAX UNITS COMMENTS
OD16 Type Buffer
Low Output Level
Output Leakage
V
OL
I
OL
-10
0.5
+10
V
µA
I
OL
= 16 mA
V
IN
= 0 to V
CC
OD162 Type Buffer
Low Output Level
High Output Level
Output Leakage
V
OL
V
OH
I
OL
2.4
-10
0.5
+10
V
V
µA
I
OL
= 16 mA
I
OH
= -2 mA
V
IN
= 0 to V
CC
OD24 Type Buffer
Low Output Level
Output Leakage
V
OL
I
OL
-10
0.5
+10
V
µA
I
OL
= 24 mA
V
IN
= 0 to V
CC
Supply Current Active
Supply Current Standby
I
CC
I
CSBY
60
8
95 mA
mA
All outputs open
CAPACITANCE T
A
= 25
o
C; fc = 1MHz; V
CC
= 5V
LIMITS
PARAMETER SYMBO
L
MIN TYP MAX UNIT TEST
CONDITION
Clock Input Capacitance C
IN
20 pF All pins except pin
under test tied to
AC ground
Input Capacitance C
IN
10 pF
Output Capacitance C
OUT
20 pF