SMC Networks TigerAccess SMC7816M Bedienungsanleitung Seite 491

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 962
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 490
L
INE
C
OMMANDS
20-31
Example
To set the timeout to two minutes, enter this command:
exec-timeout
This command sets the interval that the system waits until user input is
detected. Use the no form to restore the default.
Syntax
exec-timeout [seconds]
no exec-timeout
seconds - Integer that specifies the timeout interval.
(Range: 0 - 65535 seconds; 0: no timeout)
Default Setting
CLI: No timeout
Telnet: 10 minutes
Command Mode
Line Configuration
Command Usage
If user input is detected within the timeout interval, the session is kept
open; otherwise the session is terminated.
This command applies to both the local console and Telnet
connections.
The timeout for Telnet cannot be disabled.
Using the command without specifying a timeout restores the default
setting.
Example
To set the timeout to two minutes, enter this command:
Console(config-line)#timeout login response 120
Console(config-line)#
Console(config-line)#exec-timeout 120
Console(config-line)#
Seitenansicht 490
1 2 ... 486 487 488 489 490 491 492 493 494 495 496 ... 961 962

Kommentare zu diesen Handbüchern

Keine Kommentare